1. What is the purpose of elevator buffers?
An elevator buffer is a safety component of the elevator, tasked with absorbing the kinetic energy of the car or counterweight when it travels beyond the lower limit of travel, thereby protecting the safety of passengers and equipment.
TCVN 6396-20:2017 (equivalent to EN 81-20:2014) – Safety requirements for the construction and installation of elevators – defines a buffer as an elastic stop at the end of the elevator travel, including a braking means using liquid or springs (or other similar means). The standard also requires elevators to have buffers at the lower limit of travel for both the car and the counterweight.
Simply put, when the car (or counterweight) due to some incident (control system failure, cable slipping on the traction pulley, machine brake not holding sufficient force, etc.) travels beyond the lowest stopping floor, the buffer will receive the kinetic energy of the moving mass, bringing the car to a "smooth" stop within the acceleration limits that the human body can withstand, instead of crashing straight down onto the concrete floor of the hoistway, thereby protecting the safety of passengers and equipment.
Buffers are usually arranged in the hoistway. Buffers may also be mounted directly beneath the car or counterweight; in that case, at the position where the buffer acts on the hoistway floor, there must be a raised plinth not less than 300 mm high (clause 5.8.1.1).
For positive drive elevators (drum-driven elevators), an additional buffer must be provided above the car to operate for the upper limit of travel (clause 5.8.1.2).

2. Elevator buffers in the chain of safety equipment systems
Today's elevators are protected for safe operation in multiple layers. Under normal conditions, the control system decelerates and stops the car precisely at the floor. If the car travels past the final floor, the limit switch at the end of travel will break the safety circuit and engage the traction machine brake.
If the car descends at excessive speed, the overspeed governor will activate the safety gear, clamping the car to the guide rails. The safety gear is a safety device that operates together with the overspeed governor to protect the car when an incident occurs.

The buffer is the final layer of protection, working when the layers of protection above have not yet stopped the car completely before it hits the bottom, for example due to brake slippage, cable slipping on the pulley, or a control failure.
A common misconception is that buffers are used to "catch" the car in free fall when cables break. In reality, the free-fall scenario is handled by the safety gear of the overspeed governor. Buffers are calculated to absorb impact at a speed of approximately 115% of the rated speed of the elevator – that is, the scenario where the car travels beyond its travel range at a speed exceeding normal levels.
3. What are the types of elevator buffers?
According to Standard EN 81-20 (and the equivalent TCVN 6396-20), buffers are divided into two major groups based on how they handle impact energy:
(1) Energy accumulation buffers - energy is accumulated in an elastic element such as a steel spring or polyurethane block. Most of the energy is then returned, causing the car to bounce up.
(2) Energy dissipation buffers - energy is converted into heat, usually by oil being forced through orifice holes in a cylinder. The car stops and hardly bounces back.
On the market, these correspond to three types: spring buffers, polyurethane (PU) buffers, and hydraulic buffers.
3.1 Hydraulic buffers - the safest, suitable for all elevator configurations
A hydraulic buffer is an energy dissipation type of buffer, consisting of an oil-filled cylinder, a piston, orifice holes, and a return spring (mechanical spring or gas spring).

When the car presses down, the piston pushes oil through the orifice holes; the impact energy is converted into heat and dissipated, causing almost no rebound of the car or counterweight. The orifice design allows the braking force to be maintained almost constant throughout the travel, helping the stopping process to be smooth and controlled.
After the car is lifted, the return spring pushes the piston back to its extended position; the elevator may only run again when the electrical safety switch confirms that the buffer has returned to its original position.

Structure of a hydraulic buffer
- Advantages: Can be used for all rated speeds; smooth stopping, little rebound; shorter travel compared to energy accumulation buffers at the same speed.
- Disadvantages: higher cost; requires checking oil level, leaks, and ability to return to position; more complex structure.
- Application: Can be used for all speeds and is mandatory for elevators with a rated speed greater than 1 m/s.

3.2 Energy accumulation buffers: springs and polyurethane (PU) - only used for elevators with a rated speed not exceeding 1 m/s
The energy-absorbing buffer group operates on the same principle: when the car presses on it, the buffer is compressed and stores kinetic energy as elastic potential energy, similar to compressing a spring. In practice, there are two common forms:
- Steel spring buffers: consisting of a system of highly elastic steel springs designed to withstand large forces, mounted on a fixed vertical base in the pit. The impact energy is converted into elastic deformation; the resistance increases proportionally with compression. After being compressed, the spring expands and returns most of the energy, pushing the car back up; the car may bounce several times before coming to a complete stop.

- Polyurethane (PU) buffers: an elastic block cast from polyurethane (also known as synthetic rubber/elastomer buffers), in cylindrical form mounted on a steel base. The stiffness of the elastic material block increases progressively with the compression of the impact.
When the car or counterweight presses on it, the material block deforms under compression and accumulates kinetic energy as elastic potential energy. A portion of the absorbed energy is dissipated as heat during the compression-recovery cycle, so the recovery reaction force is smaller and the car rebounds less compared to spring buffers.

- Advantages: simple structure, low cost, quick installation, virtually no need for complex maintenance. PU buffers do not rust like springs, making them suitable for elevators with low pits.
- Disadvantages: The kinetic energy when the car/counterweight presses on the buffer is mainly absorbed rather than dissipated, so there is a tendency to push the car back up (most evident in spring buffers).
Spring buffers may rust in humid hoistways; PU buffers age (become brittle, crack, deform, etc.) over time, are sensitive to temperature, humidity, oil and grease, and need periodic replacement as recommended by the manufacturer.
- Application: Unlike hydraulic buffers, according to TCVN 6396-20:2017 (clause 5.8.1.5), both PU buffers and spring buffers may only be used for elevators with a rated speed not exceeding 1 m/s.

Note on PU buffer quality: In 2026, the European Commission published the results of elevator buffer testing according to EN 81-20 and EN 81-50 under the 2025 Joint Action on Product Compliance (JACOP) program.
Of the 40 samples taken in six countries, 28/33 PU samples (about 85%) failed, while all 7 hydraulic buffer samples passed. The main defect was that the maximum braking acceleration exceeded the permitted limit: the car was decelerated too abruptly, increasing the force exerted on the people inside.
Market surveillance authorities contacted 23 businesses to request responses and remedial measures, and also banned the sale of 5 PU buffer samples, including products sold through Chinese e-commerce platforms. This result shows that when choosing PU buffers, full test documentation according to TCVN 6396-50 (EN 81-50) must be required.